Home · Analysis · Radiation and stable isotopes · Artificial Optical Radiation

Artificial optical radiation

Artificial_optical_radiation_White_Lab

Whitelab carries out risk assessments of exposure of workers to coherent and non-coherent artificial optical radiation (AOR) sources, in line with the requirements of Italian Legislative Decree No 81/2008.

Our laboratories are staffed with highly qualified Laser Safety Technicians/Officers (TSL/ASL) and Optical Radiation Safety Experts (ERO) who guarantee a complete and integrated service, including training and information activities.

Artificial optical radiation includes all components of the electromagnetic spectrum of wavelengths between 100 nm and 1 mm, with the spectral bands of infrared (IR), visible (VIS) and ultraviolet (UV). Optical radiation sources can be classified into two families: coherent (LASER) and non-coherent sources.

L.A.S.E.R. (Light Amplification by Stimulated Emission of Radiation) devices are coherent artificial optical radiation sources manufactured and used in many sectors: medical, aesthetic, telecommunications, information technology, materials processing (cutting, welding, marking), metrology and measurements, scientific research laboratories, consumer goods, entertainment sectors, etc. All artificial optical radiation sources other than laser sources are non-coherent sources.

The health and safety risks to be prevented in the case of workers working with AOR sources are both direct and indirect, with particular reference to the harmful short- and long-term effects that may occur to the eye, in all its parts (cornea, crystalline lens and retina), and to the skin.

The main acute effects to the skin are UV radiation-induced erythema and photodermatitis, while the carcinogenicity of UV radiation causing skin cancer, and photoageing are the main effects in the long term. As regards the eye, the main acute effects are photoconjunctivitis, photokeratitis and phototoxic maculopathy, while some chronic effects are cataracts and eye tumours.

Italian Legislative Decree No 81/2008 and following amendments lays out the obligation of the employer to carry out an assessment of the risk arising from exposure to artificial optical radiation within their company, in order to identify and adopt appropriate prevention and protection measures.

The risk assessment analyses the following elements:
  • The census of equipment containing AOR sources
  • The level, level range and duration of exposure to AOR
  • The exposure limit values laid down in Italian Legislative Decree No 81/2008
  • The direct effects on workers' health and safety
  • The indirect effects (temporary blinding, explosions or fire starting)
  • The possibility of using alternative equipment to reduce exposure levels
  • The availability of remedial actions to minimise exposure levels
The Risk Assessment Document (DVR) requires updating every four years in accordance with Italian Legislative Decree No 81/2008, Title VIII, Chapter V, and is subject to revision if a change occurs that makes it obsolete. It contains:
  • The detailed outcome of the assessment
  • Documentation of the absence of risks if the exposure is below the permitted limits
  • Supplementary documents attached if the assessment is carried out by instrumental investigation
  • The Operational Safety Plan (POS) in the case of temporary or mobile construction sites
  • The Single Interference Risk Assessment Document (DUVRI) in the event that workers of external companies are potentially exposed to such risk
Pursuant to Article 218 of Italian Legislative Decree No. 81/2008, health surveillance for workers exposed to the AOR risk is carried out periodically, usually once a year or at a lower frequency decided by the Competent Doctor, with particular regard to risk-sensitive workers, taking into account the results of the risk assessment submitted by the Employer. Health surveillance is carried out to timely prevent and detect adverse health effects, as well as to prevent long-term adverse health effects and risks of chronic diseases resulting from exposure to optical radiation.

Whitelab laboratories' Laser Safety Technicians/Officers (TSL/ASL) and Tecnici (ERO) Optical Radiation Safety Experts (ERO) carry out all activities in support of the Employer necessary to comply with the current legislation on coherent artificial optical radiation.

Find out more about Whitelab services

Laser Safety Technician and Optical Radiation Safety Expert
  • Census of equipment and devices containing AOR sources
  • Identification of all activities involving AOR sources
  • Verification of how the sources are used and their technical specifications
  • Verification of personal protective equipment (PPE) and collective protective equipment provided by the employer
  • Analysis of the technical, organisational and procedural prevention and protection measures adopted
  • Assessment of workers' exposure to AOR sources based on the information provided by the obligated party and manufacturers and supported by calculations
  • Elaboration and implementation of actions including technical and/or organisational measures if exposure limit values are exceeded
  • Identification of Laser Controlled Areas/Limited Access Areas with indication of necessary protective equipment
Training
Whitelab’s Laser Safety Technicians and Optical Radiation Safety Experts meet the requirements of Italian Legislative Decree 06/03/2013 and, as Safety Trainers, they support the Employer for training and information obligations.

According to Art. 37 of Italian Legislative Decree No 81/2008, the relevant State-Region Agreements on training, and Art. 184 of Italian Legislative Decree No 81/2008, all workers must be trained on the specific risks of their job and the contents of the specific training are defined in relation to the job of the worker.

According to Art. 36 of Italian Legislative Decree No 81/2008, information must be provided to all workers directly or indirectly involved in exposure to artificial optical radiation sources. In particular, it is recommended to provide specific information/training for workers when the risk assessment cannot be concluded with the ‘justification’ of the sources [see ‘Operational indications for the prevention of risks from Physical Agents pursuant to Italian Legislative Decree No 81/08 - Part 6: Artificial Optical Radiation’ (2023)].


Would you like to receive more information or schedule a customised consultation for your company? Please, fill out the form and we will get back to you as soon as possible

"*" indicates required fields

Name and surname*
This field is for validation purposes and should be left unchanged.

Analysis and services

SERVICES

Legionella

Microbiological testing, sampling, risk assessment document, consultancy and Risk Assessment.

SERVICES

EC health mark

Testing and services for obtaining and maintaining the EC health mark.

SERVICES

Pharmaceutical packaging

Testing and services to test the pharmaceutical packaging effectiveness to ensure the maintenance of sterility.

SERVICES

Biocompatibility

Whitelab's offer for the biological evaluation of your Medical Device with biocompatibility studies.

SERVICES

REACH & RoHS

Testing and services to ensure the compliance of consumer products.